Luoyang Blue Energy Technology Development Co., Ltd. replaced the burner of a branch of Sinopec, this time using our WL-FBNQ flat flame radiation wall low NOx burners, after the use of remarkable results:
1.The temperature of the heating furnace medium out of the furnace meets the process production requirements.
2.The burner combustion condition is obviously improved, and the combustion is complete and stable. There is no yellow flame, the flame is blue flame, the flame type is straight and strong, not floating and not even. Attached to the wall spray to the furnace wall flame height between 1.2m to 1.5m. 3.
3.Device air supply system for natural ventilation, divided into two hearths, sharing a convection chamber and smoke exhaust. The combustion only replaced the west side of the hearth burner, the east side of the hearth to maintain the original equipment, the total exhaust NOx emissions from the original 109㎎/Nm³ down to 65㎎/Nm³, the effect is remarkable.
4.The burner design is easy to operate, easy to dismantle the lance, reducing the burner maintenance cost.